Some aspects of Experimental Testing of seismic behaviour of masonry walls and models of masonry Buildings
January 6, 2012 by Confined Masonry Network
Filed under Existing Guidelines
Comments Off
Authors: Miha Tomazevic
Reference: ISET Journal of Earthquake Technology ,Dec.2000
Summary:
In order to experimetnally simulate failure mechanism in masonry wals in buildings structural system, scale down models were tested under monotonic, cyclic, sinusoidal and earthquake response lateral displacement-time histories to understand infuluence of different loading procedures on seismic resistance of walls.
Conclusion & Future Goals:
Monotonic procedure resulted into higher values of lateral resistance and larger ultimate displacement than in cyclic loading. Similarly higher value of lateral resistance were measured in dynamic tests then in static experiements. Also findings indicate that seismic behaviour of structural system can be studied in scale-down tests, and not the behaviour of structural details.
Engineered design of masonry buildings:fifty years development in Europe
January 6, 2012 by Confined Masonry Network
Filed under Existing Guidelines
Comments Off
Authors: A W Hendry (Scotland)
Reference: Struct.Engng Mater.2002;4:291-300
Summary:
Essential problems of verall stabiltiy and safety and the design of walls in compression and lateral loads have been addressed.
Masonry Shear Walls subjected to Cyclic Loading:Influence of Confinement and Horizontal Reinforcement
January 6, 2012 by Confined Masonry Network
Filed under Existing Guidelines
Comments Off
Authors: Jao P.Gouveia and Paulo B.Lourenco (Portugal)
Reference: Tenth North American Masonry Conference, June 3-6, 2007, St Louis, Missouri, USA
Summary:
Experiments were conducted on masonry walls (scale-down 1:2) subjected to in-plane cyclic actions and constant pre-compression for evaluation of shear strength, ductility, energy dissipation and stiffness. Also discussed on possibility of replacing the filling of the vertical joints by interlocking and horizontal bed joint reinforcement and need for filling vertical joints in confined masonry solutions.
Experimental and Numerical study of Confined Masonry Wall under Cyclic Loading
December 21, 2011 by Confined Masonry Network
Filed under Existing Guidelines
Comments Off
Authors: Miha Tomazevic and Iztok Klemenc
Reference: Earthquake Engg.and Structural Dynamics,Wiley Interscience, March 1997
Summary:
Experimental & Numerial simulation were carried out to investigate the response of CM walls on three speciemens (size 870x1330mm) each of red brick, concrete block and concrete wall with horizontal reinforcement. The models were excited cyclically according to certain dispacement history. Lateral force withstand by these spcimens were 5.6kN,4.29kN and 1.92kN. First significant cracks is further studied numerically to analyse the CM wall.
Conclusion and future Scope:
Based on the study, lateral strength, load-displacement curves, stiffness degradation, and energy dissipation capacity were evaluated. The stiffness degradation and energy dissipation capacity is highest in RB, followed by CW and CWHR. Stress-strain relationship alongwith guidance for analysis of CM walls like modulus of elasticity, masonry yield strength (thereby yield strain), limiting strain, ultimate strain, stress-strain curve etc., were outlined.
Seismic behaviour of Confined Masonry Walls
November 4, 2011 by Confined Masonry Network
Filed under Existing Guidelines
Comments Off
Authors: Miha Tomazevic and Iztok Klemenc
Reference: Earthquake Engg.and Structural Dynamics,Wiley Interscience, March 1997
Summary:
Rational method for modeling of seismic behaviour of CM walls has been carried out based on test results on plain and CM wall with h/l ratio 1.5, made at 1:5 scale. A trrlinear model wherein resistance is calculated as combination of shear resistance of plain masonry and dowel effect of tie-collumn reinforcement. THe method was verified for prototype CM wall with h/l ratio equal to 1.
Conclusion and future Scope:
Monotonic behaviour and actual boundary restraints are assumed in the case of determination of effective stiffness of CM wall panel. Stiffness degradation has been modelled as a function of effective stiffness of the panel and damage index at characteristic limit states. Good coorelation between predicted and experimental envelopes has been obtained
Experimental and analytical studies on earthquake resisting behaviour of confined concrete block masonry structures
November 3, 2011 by Confined Masonry Network
Filed under Existing Guidelines
Comments Off
Authors: Norio Hori, Norio Inoue, Dangol Purushotam, Tetsuya Nishida and Jun Kobayashi (Japan)
Reference:Earthquake Engg. and Structural Dynamics,Wiley Interscience, July,2006
Summary:
Wall specimens made of concrete blocks confined with column ties were tested under cyclic lateral load and simulated by a rigid body spring model that models non-linear behaviour by rigid bodies and boundary springs. Three tests were performed with varying axial stresses and shear span ratio. The results of studies outline the resisting mechanism, indicating that a rigid body spring model is considered appropriate for analysing this type of structures.
Conclusion & Future Scope:
At different axial stresses, shear strength increased with larger axial stress because the shear strength of mortar joint increased. In case different shear span ratio, shear strength decreased with large shear span ratio: SSR – 0.55 for 2-3 story; 1 – 5-6 story and 1.5 for 7-8 storey building. Thus, the strength of CM system is primarily controlled by inclined compressive force on a masonry wall and tension strength of tie column reinforcement. In case of large axial stress on tension side due to overturning moment in high reise building, ERD must consider a lower shear resisting capacity of masonry, such as strength and energy dissipating capacity.
Rigid element model for in plane dynamics of masonry walls considering hysteretic behaviour and damage
November 3, 2011 by Confined Masonry Network
Filed under Existing Guidelines
Comments Off
Authors: Siro Casolo,and Fernando Pena
Reference: Earthquake Engg.and Structural Dynamics,Wiley Interscience, pp 1029-1048, Vol.36 -Feb.2007
Summary:
Specific rigid element approach is propsosed for inplane dynamic analysis of masonry walls whose seismic performance is strongly related to mechanical deterioration and hysteretic energy disssipation. A mechanistic ‘rigid body spring model was adopted which consists of a collection of plane quadrilateral rigid elements connnected to each other by two normal spring and one shear spring at each side. Separate hysteretic law was assigned for axial and shear deformation between elements. The performance of present approach shown by numerical validation & comparisons with experimental and numerical tests.
Conclusion & Future Scope:
Investigation of complex interaction between strong ground motion and expected damage in relation to the hysteretic and energy dissipation capacity of the material.
Backbone Model for Confined Masonry Walls for Performance Based Seismic Design
November 3, 2011 by Confined Masonry Network
Filed under Existing Guidelines
Comments Off
Authors: Zahra Riahi, Kenneth J Elwood, S.M. Alcocer (Canada)
Reference: J. Structural Engg., ASCE, June 2009
Summary:
Performance based model is proposed on the basis of both monotonic and reversed cyclic experiements assembled in an database and derived through iterative linerar regression analysis.Specimens with two tie columns, one on either edge of the wall; multiple longitudinal rebar per confining element; no bed joint reinforcement; no openings within confined panel; and a H/L ratio between 0.7-1.2 are considered. Effect of opening on strength characteriestics, capability of exisitng models to predict seismic behaviour for CM walls were studied and validity of predictive equations for specimens with bed joint reinforcement and high axial load were investigated. Models for cracking shear strength; effect of openings; max.shear strength; crakcing drift capacity; and Ultimate drift capacity were developed.
Conclusion & Future Scope:
The proposed models fails to match recorded response for aspect ratio above 1.2, tie column with one longi.bar, axial stress greater than 0.12fm. Future tests recommended for CM walls with openings; panel reinforcement; multiple confining elements, or high axial stress. Tie column transverse reinforcement is one of the design variable that proved insignificant to the ultimate deformation equaiton of this study, hence the factor needs to be studied. As the current CM codes criteria are mainly rely on conventional force-based equations developed for URM/RM walls, hence the effect of confining element is overlooked, hence incapable of predicting the recorded response with sufficient accuracy.
Risk Management Solutions supports Network
September 17, 2009 by Confined Masonry Network
Filed under Existing Guidelines
Comments Off
Risk Management Solutions, a risk modeling company based in Newark, California, is supporting an initial phase of the Confined Masonry Network. At $50,000 grant is being used to support the development of a global design guideline for confined masonry construction, a template for a construction guideline, and the development of a research agenda.