Some aspects of Experimental Testing of seismic behaviour of masonry walls and models of masonry Buildings
January 6, 2012 by Confined Masonry Network
Filed under Existing Guidelines
Authors: Miha Tomazevic
Reference: ISET Journal of Earthquake Technology ,Dec.2000
Summary:
In order to experimetnally simulate failure mechanism in masonry wals in buildings structural system, scale down models were tested under monotonic, cyclic, sinusoidal and earthquake response lateral displacement-time histories to understand infuluence of different loading procedures on seismic resistance of walls.
Conclusion & Future Goals:
Monotonic procedure resulted into higher values of lateral resistance and larger ultimate displacement than in cyclic loading. Similarly higher value of lateral resistance were measured in dynamic tests then in static experiements. Also findings indicate that seismic behaviour of structural system can be studied in scale-down tests, and not the behaviour of structural details.